Unit 1 227 Kva
Unit 2 192 Kva
Unit 2 66 Kva
Unit 1:
Ground floor: 3970mm to underneath of slab, 3470mm to underneath of steel cellular beams
1st floor: 3750mm to underneath of slab, 3250mm to underneath of steel cellular beams
Unit 2:
Basement: 3890mm to underneath of slab, 3390mm to underneath of steel cellular beams
Ground floor: 3970mm to underneath of slab, 3470mm to underneath of steel cellular beams
Unit 3:
Basement: 3890mm to underneath of slab, 3390mm to underneath of steel cellular beams
Ground floor: 3970mm to underneath of slab, 3470mm to underneath of steel cellular beams
Retail areas -5 kN/m2 [4 + 1 kN/m2]
Plant areas - 7.5 kN/m2
Out of hours from Oxford street
Landlord installed extract and intake ductwork to roof level plant. Ducts terminated at the perimeter of each demise for tenant connection. Landlord installed dedicated tenant containment tray located at the perimeter of the unit and routed through to the roof level plant. Demised plant zone and plant deck grillage for tenant plant.
New sprinkler isolation valve and flow switch to be provided at each level (one per floor) to back of house. Sprinkler pipe work within the unit by the tenant.
Fire alarms within the unit by tenant. Alarm to be interfaced to the Landlord interface panel located in the landlord back of house corridor adjacent the unit.